Product TOP
For measurements and control in diverse field uses. Multifunction counter with RS-232C interface
- RS-232C standard function
- Peak Hold Function Convenient for Statistical Measurement
- Convenient External Input Functions for Automatic Measurement
- Display Resolution Switching
- Data Storage
- Reset/Preset/Restart
- Detecting Reference Point of Measurement Unit
- Scaling Flicker Control
Specifications
| Specifications | |||
|---|---|---|---|
|
Magnescale reserves the right to change product specifications without prior notice. |
|||
| Model | LY72 | ||
| Specifications by application | Applications as gauge (set axis labels A, B, and C) | Applications as scale (set axis labels X, Y, and Z) | |
| Number of input shafts | 1 to 3 axis | ||
| Display | 7 digits and minus display, Color amber | ||
| Display data | Current (1st axis, 2nd axis, addition axis), maximum, minimum and peak-to-peak values | Current (1st axis, 3rd axis, addition axis) | |
| Input resolution |
|
||
| Display resolution | Measuring unit input resolution or higher and supported inch units | ||
| Input signal | A/B quadrature signal, Z signal (Conforms to EIA-422) | ||
| AlarmDisplay | Measuring unit disconnected, Excess speed, Maximum display amount exceeded, Power failure, Error in stored data | ||
| Reset | Current value reset, Alarm cancel | ||
| Restart | Restart of peak value calculation for each axis/all axes | – | |
| Preset | It is possible to store/edit up to three values for each axis. | ||
| Master calibration function | The master calibration value is relocated when going past the reference point after the power is turned on. | – | |
| Reference point operations | It is possible to store/edit one value for each axis (when not using the master calibration function). | ||
| Hold function |
|
Display hold | |
| Linear compensation | A fixed compensation amount is applied to the measuring unit’s count value. Compensation amount Standard: ±600 µm/m (Expanded: ±1000 µm/m) | ||
| Scaling | 0.100000~9.999999 | ||
| I/O |
|
||
| Timer output | OFF/0.2/0.5/1/5/10/30/60/300秒 | ー | |
| Output data | Current value/Maximum value/Minimum value Peak-to-Peak value | Current value | |
| Power supply | DC 12 V Rating 0.75 A, Max. 1 A AC 100 V to 240 V ±10 % When using the AC adaptor PSC-22A (For U.S. only) or PSC-23A (For Europe and other countries) *Option | ||
| Power consumption | MAX. 32 VA connected at the AC adaptor. | ||
| Temperature | Operating : 0~40℃ (non condensing), Storage : -20~60℃ (non condensing) | ||
| Mass | Approx. 1.5kg | ||
Dimensions
| Product name | 2D | 3D |
|---|---|---|
| LY72 | Download | - |
Instruction manual
| Product name | Japanese | English | Deutsch | Simplified Chinese | Traditional Chinese | |
|---|---|---|---|---|---|---|
| LY72 | install | Download | Download | Download | Download | Download |
| LY72 | operation | Download | Download | Download | Download | Download |
Setup manual
| Product name | Initial setup | Display resolution | Preset | Angle display |
|---|---|---|---|---|
| LY72 | Download | Download | Download | Download |
*Please contact us if you cannot download the file.
Accessory
LY72
AC Adapter
| PSC-21A | AC adapter (AC100V for Japan) | |
| PSC-22A | AC Adapter (AC 120V for US) | |
| PSC-23A | AC adapter (AC220 to 240V for other countries except for EU) | |
Catalog
Please refer to the Digital Gauge General catalog.