Digital Gauge

LT80/MG80-MA/
MG80-CM

Product TOP

LT80 Clear and easy to use HMI functions

  • 7-inch touch screen LCD display
  • Multiple measurement modes (current value, MIN, MAX P-P, ADD/SUB.) Can be used for defective part identification, trend management, part sorting and tolerance judgement by using 2 or 4 state comparator function
  • Displays I/O status
  • Three data storage and parameter setting options (SD card, USB, and Ethernet)
  • Multiligual support (Japanese, English, German)

MG80 Expandable multi-axis measurement module system

  • Connect up to 32 Magnescale DK- or DT-series gauges (via MT adaptor)
  • DIN rail mount for easy installation (MG80 and LZ80)
  • High speed latch (via MG80-LM latch module)
    • -Synchronized angle and position measurement is available*1 by connecting a linear or rotary encoder*2
    • *1 16 axes max.
    • *2 Requires A/B Quadrature encoder signal (EIA-422 compliant).
    • -Latching data with specific angles or distances can be saved to the LT80.

LZ80 I/O module

  • Equipped with 8 inputs and 8 outputs
  • Functions can be assigned freely from LT80
  • Up to two MG80 I/O modules can be connected to one MG80-MA

Specifications

Display unit
Model LT80-NE
Power consumption 14W or less
Maximum connectable units 4 units of MG80-MA*1
Measurement screen Measurement display Display measurement values of 2, 4, 6, 8 or 16 channels, Alarm display, Comparator group, Measurement mode, Measurement bar graph, Reset, Preset
I/O information I/O condition monitoring (All I/O of display unit and main module)
Setting menu Measuring unit setting Resolution, direction, with or without reference point connected to MG80-CM
Display setting Set number of channels to display: 2, 4, 8 or 16 channels
Measurement mode Measurement mode setting of each channel (current, MAX, MIN, P-P)
Comparator value setting 8 groups with 2 stages, or 8 groups with 4 stages per channel Default setting of each CH
I/O setting I/O function assignments of LT80-NE, I/O function assignments of connected LZ80-K, Reference point detection, Reset, Preset,
Comparator output, Alarm, Reference point passed, Each channel address, Change measurement mode
Calculation Maximum of 16 combinations of add/subtract calculations per MG80-MA module
Maintenance display Main body information, Service usage (Software update for LT80 and MG80)
General I/O Photo coupler insulated 4 inputs and 4 outputs (functions set on main unit)
Interface connector For control: RJ45x1 (shielding compatible)
For data: RJ45x2 (shielding compatible)
SD card slot x 1, USB A connector x 1
Power input connector Terminal block x 1 (3 poles), DC jack (EIAJ4) x 1

*1 When using LINK function of MG80-MA dedicated port and MG80-MA

Main module
Model MG80-MA1/MG80-MA2
Power consumption 2.4W or less
Maximum connectable units 16 MG80-CM units, 2 LZ80-K units*1
I/O 7-pole connector Photo coupler insulated 4 input, 1 output
MG80-MA1: Current sinking type
MG80-MA2: Current source type
Interface connector For data: RJ45 x 2 (sheilding compatible)
Communication protocol 100BASE-TX
Transmission speed 100 Mbit/s
Maximum cable length 20m (CAT5e shielding type recommended*2)
Setting menu Rotary switch for setting unit number

*1 Per each MG80-MA1/MA2. Total system maximum: 4 MG80-MA1/MA2 units, 32 MG80-CM units, 8 LZ80-K units.
*2 The customer must provide the communication cables.

Counter module
Model MG80-CM
Power consumption 2.0W or less (Measuring unit excluded)
Compatible measuring units DK series, DT series (via MT)
Alarm Frequency response exceeded, Measuring unit not connected, Cable breakage
Latch module
Model MG80-LM
Data refresh rates 100µs (measured data acquisition only)
400µs (Applies
to all functions such as reference point, calculations, comparator function, Max, Min and P-P)
Power consumption 2.0W or less (Encoder excluded)
Encoder signal input A/B/Z (reference point)
Voltage differential line receiver (EIA-422 compliant)
A / B signal input minimum phase difference 50ns
Power supply for connected encoder DC5V 500mA (Max)
Alarm Input response frequency exceeded, encoder not connected, Cable breakage
I/O module
Model LZ80-K1/LZ80-K2
Power consumption 2.0W or less
I/O 9-pole connector × 2 Photo coupler insulated 8 input, 8 output
LZ80-K1: Current Sink
LZ80-K2: Current Source
LT80/MG80/LZ80
Supply voltage DC10.8~26.4V
Operating temperature/humidity range 0 to +50℃ (No condensation)
Storage temperature/humidity range −20 to +60℃ (20 to 90%RH)

*Please refer to the LT80 operation manual (Ver 1.04.00 or later) for details on the functions.

Magnescale reserves the right to change product specifications without prior notice.

Dimensions

*Please contact us if you cannot download the file.

Instruction manual

Product name Japanese English
LT80-NE Download Download
MG80-MA1 / MG80-MA2 Download Download
MG80-CM Download Download
MG80-LM Download Download
LZ80-K1 / LZ80-K2 Download Download

Operating manual

Product name English Version
LT80-NE Download Ver 1.06.00 or later
Command Reference Manual
LT80-NE Download Ver 1.07.00 or later
PLC Link Manual
LT80-NE Download Ver 1.05.00US or later
LT80-NE Download Ver 1.05.00JP or later
LT80-NE Download Ver 1.04.00 or later
LT80-NE Download Ver 1.03.00US or later
LT80-NE Download Ver 1.02.00 or later

*Please contact us if you cannot download the file.

Accessory

LT80/MG80-MA/MG80-CM

AC Adapter

PSC-21A AC Adapter for LT80 (AC 100 V for Japan)
PSC-22A AC Adapter for LT80 (AC 120 V for U.S.)
PSC-23A AC Adapter for LT80 (AC 220 to 240 V for Europe and other region)

Latch module

MG80-LM Data Latch module for MG80-MA

I/O Modul

LZ80-K1/K2 I/O Modul for MG80-MA, MG80-PN, MG80-EI, MG80-EC

Catalog

LT80/MG80 Series Japanese LT80 Catalog Japanisch PDF
LT80/MG80 Series English LT80 Catalog English PDF
LT80/MG80 Series Deutsch LT80 Catalog Deutsch PDF