Product TOP
Head cable unit
- Non-contact detection
- Magnetic detection system for excellent resistance to dust, oil, vibrations and shocks.
- Detects linear position and displacement and produces analog signal output when connected to the SL700 series.
- A wide range of models is available so you can select the best model for your specific application.
Specifications
| Specifications | ||||
|---|---|---|---|---|
|
*1 Refer to Dimensions. Magnescale reserves the right to change product specifications without prior notice. |
||||
| Model | PL101-R | PL101-RH | ||
| Protective design grade | Equivalent to IP50 | Equivalent to IP67(exclude Connecter) | ||
| Reference point | Included | |||
| Resolution | 1, 2, 5 or 10 µm (MJ620), 1 µm (MJ600), 2 or 10 µm (MJ500) | |||
| Accuracy (20°C) | ±10 µm (when combined with the SL700) | |||
| Clearance*1 | 0.35±0.1 mm | |||
| Offset | ±0.2 mm | |||
| Attitude change | Pitch*1 | ±0.1° | ||
| Yaw*1 | ±0.2° | |||
| Roll*1 | ±0.2° | |||
| Output signal | 1 Vp-p Analog output, differential output | |||
| Power supplyPower supply voltage | DC 5V±5% | |||
| Power consumption | Max. 0.8 W | |||
| Maximum response speed | 6.4 m/s(when combined with the MJ600(resolution: 1 µm)) | |||
| Head cable length | 300 mm | 3000 mm | ||
| Mass | 60 g | 150 g | ||
| Operating temperature | 0°C to +45°C | |||
| Storage temperature | -20°C to +50°C | |||
| Extension cable(Option) | CE08-01: 1 m, CE08-03: 3 m, CE08-05: 5 m, CE08-10: 10 m, CK-T12: 1 m, CK-T13: 3 m, CK-T14: 5 m, CK-T15: 10 m | |||
Catalog
Please refer to the Digiruler General catalog.