MD21
 

High accuracy detector unit for position control

  • Generates A/B phase output signal with a resolution of 0.1 µm for feedback to an NC unit and up/down output signal for a display unit.
  • Selectable resolution and output pulse width
  • Compact design of 32 x 171 x 144 mm / 1.3″ x 6.7″ x 5.7″ (W x H x D) permits the detector to be located in tight spaces as in a switchboard.
  • Operable from 5V power supply. With the optional PU20 power supply unit, power for up to 3 axes can be supplied.
  • A/B phase signal, up/down signal, zero point signal and alarm signal outputby differential line driver.
Specifications
Model
MD21
Resolution
0.1, 0.2 µm selectable
Output pulse width
0.25, 0.5, 1, 2, 2.5, 5, 10 or 20 µs selectable
Max. response speed
See table below
Output signal
A/B phase and up/down output by differential line driver (equivalent to SN75113); both simultaneous
Zero point signal
In synch with scale signal
Alarm
Max. response speed exceeded, cable broken or disconnected, other circuit errors
Reset
Use reset key operation or external input
Power supply
+ 5 V DC + 5% -2%
Power consumption
Max. 3 W
Operating temperature
0 °C to 50 °C / 32 °F to 122 °F
Storage temperature
-10 °C to 70 °C / 14 °F to 158 °F
Dimensions
32 x 171 x 144 mm/ 1.3" x 6.7" x 5.7" (W x H x D)
Mass
0.8 kg/ 1.76 lbs

 

Maximum response speed
Resolution

(µm)
Output pulse width (µs)
0.25
0.5
1
2
2.5
5
10
20
0.1
18
9
4.5
2.2
1.8
0.8
0.4
0.2
0.2
30
18
9
4.5
3.6
1.8
0.8
0.4

 

Zero point response speed
Resolution (µm)
Response speed (m/min)
0.1
0.15
0.2
0.3