High accuracy detector unit for position control
- Generates A/B phase output signal with a resolution of 0.1 µm for feedback to an NC unit and up/down output signal for a display unit.
- Selectable resolution and output pulse width
- Compact design of 32 x 171 x 144 mm / 1.3″ x 6.7″ x 5.7″ (W x H x D) permits the detector to be located in tight spaces as in a switchboard.
- Operable from 5V power supply. With the optional PU20 power supply unit, power for up to 3 axes can be supplied.
- A/B phase signal, up/down signal, zero point signal and alarm signal outputby differential line driver.
Specifications
| Model |
MD21
|
| Resolution |
0.1, 0.2 µm selectable
|
| Output pulse width |
0.25, 0.5, 1, 2, 2.5, 5, 10 or 20 µs selectable
|
| Max. response speed |
See table below
|
| Output signal |
A/B phase and up/down output by differential line driver (equivalent to SN75113); both simultaneous
|
| Zero point signal |
In synch with scale signal
|
| Alarm |
Max. response speed exceeded, cable broken or disconnected, other circuit errors
|
| Reset |
Use reset key operation or external input
|
| Power supply |
+ 5 V DC + 5% -2%
|
| Power consumption |
Max. 3 W
|
| Operating temperature |
0 °C to 50 °C / 32 °F to 122 °F
|
| Storage temperature |
-10 °C to 70 °C / 14 °F to 158 °F
|
| Dimensions |
32 x 171 x 144 mm/ 1.3" x 6.7" x 5.7" (W x H x D)
|
| Mass |
0.8 kg/ 1.76 lbs
|
Maximum response speed
|
Resolution
(µm)
|
Output pulse width (µs)
|
|
0.25
|
0.5
|
1
|
2
|
2.5
|
5
|
10
|
20
|
|
0.1
|
18
|
9
|
4.5
|
2.2
|
1.8
|
0.8
|
0.4
|
0.2
|
|
0.2
|
30
|
18
|
9
|
4.5
|
3.6
|
1.8
|
0.8
|
0.4
|
Zero point response speed
|
Resolution (µm)
|
Response speed (m/min)
|
|
0.1
|
0.15
|
|
0.2
|
0.3
|
|