This slim type magnetic scale system the outputs position signals for machine tools and other equipment that require high precision positioning

  • Measuring length (ML): 70-2,040mm
  • Accuracy (20°C): 3+3ML/ 1000µm p-p 5+5ML/ 1000µm p-p
  • Minimum resolution: 0.05µm
  • Maximum response speed: 50m/min
  • Vibration resistance: 150m/s2
  • Impact resistance: 300m/s2
 
Specifications
Model SR74 SR75
Measuring length (ML) 70 – 2040 mm
70, 120, 170, 220, 270, 320, 370, 420, 470, 520, 620, 720, 770, 820, 920, 1020, 1140, 1240, 1340, 1440, 1540, 1640, 1740, 1840, 2040
Thermal expansion coefficient (/°C) 12 ± 1 x 10^-6 / °C
Output signal A/B Reference point line driver signal (compliant with EIA-422) Incremental serial bidirectional signal
(compliant with EIA-485
Accuracy (at 20 °C) ML:mm 3+3ML/1000 µm p-p or 5+5ML/1000 µm p-p
Resolution Selectable from 0.01, 0.05, 0.1, 0.5 and 1.0 µm (Set at factory shipping)
Reference point None, Center point, Multipoint (40 mm pitch),
Reference mark (standard pitch: 20 mm).
User selected point (1 mm pitch)
None, Center point,
User selected point (1 mm pitch)
Power supply voltage DC 4.75 – 5.25 V (At cable connection end)
Consumption current 200 mA (at 120 Ω terminal) max.
Imrush current 2A max. (When the power supply rise time is 10ms)
Maximum response speed

50 m/min (Resolution: 0.01 µm,
Minimum phase difference: at 50ns)

200 m/min (User-selected resolution setting)
Vibration resistance 150 m/s² (50Hz~3kHz)
Impact resistance 350 m/s² (11ms)
Protective design grade IP54 (Air purge not included), IP65 (Air purge included)
Other protections Oil lubricant can also be used under severe enviromental conditions
Power supply protection In the case of errors such as reverse connected power supply or over voltage, the internal fuse is cut to protect the power being supplied and wiring
Safety standards FCC Part 15 Subpart B Class A. ICES-003 Class A Digital Device.
EN55011 Gp1 Class A, EN61000-6-2. Safety standards not applicable (60 V DC or less)
Operating temperature range (°C) 0 ~ +50 °C
Storage temperature range (°C) -20 ~ +55 °C
Mass Approx. 0.27kg + 1.36kg/m
Slider sliding resistance 1N or less