| Model |
MJ100
|
MJ110
|
| Power supply |
5 V (4.5 V to 6 V)
|
12 V to 30 V (11 V to 31 V)
|
| Power consumption |
4 W
|
3 W
|
| Output interface |
Line driver (EIA-422)
|
Open collector (IoL = 50 mA max.)
|
| Outputs |
A/ B phases, Z phase, U/V/W phases, alarms
|
A/ B phases, Z alarms
|
| Number of divisions |
1000, 960, 800, 512, 500, 480, 400, 256, 240, 200, 128, 120, 100, 80, 64, 40
and 1/2 of each of these (which does not satisfy the synchronized reference point specifications.)
|
Maximum
response
frequency |
1000
divisions |
6 KHz
(1800 m/min when connected to PL25; 720 m/min when connected to PL60)
|
600 KHz
(180 m/min when connected to PL25; 72 m/min when connected to PL60)
|
500
divisions |
15 KHz
(4500 m/min when connected to PL25; 72 m/min when connected to PL60)
|
1.5 KHz
(450 m/min when connected to PL25; 180 m/min when connected to PL60)
|
200
divisions |
42 KHz
(12600 m/min when connected to PL25; 72 m/min when connected to PL60)
|
600 KHz
(1200 m/min when connected to PL25; 4802 m/min when connected to PL60)
|
120
divisions |
70 KHz
(21000m/min when connected to PL25; 72 m/min when connected to PL60)
|
600 KHz
(2220 m/min when connected to PL25; 888 m/min when connected to PL60)
|
| Minimum phase difference |
100 ns
|
1 µs
|
| Alarms |
Speed alarm (minimum phase difference time or maximum response frequency);
Level alarm (0.4 Vp-p or less); Minimum alarm time: approximately 400 ms
|
| System startup time |
Within 0.5 seconds after the power comes on line
|
| External dimensions |
138 x 93 x 26 (mm) / 5.43" x 3.66" x 1,024" including protrusions
|
| Compatible head unit |
PL25 or PL60
|
| Operating temperature |
0 °C to 45 °C / 32 °F to 114 °F
|
| Storage temperature |
-20 °C to 60 °C / -4 °F to 140 °F
|
| Mass |
350g/ 0.77Ibs
|
| Supplied accessories |
Manual, output connector, connector cap, mounting screws
|
| Options |
SET-P16-1 (for external reference point) Scale extension cable, external reference point extension cable
Output connector with cable
|