The “MG” Series is a modular gauging system that allows for flexible, multi-point measuring, with built-in software for today’s most popular output protocols. Because of its modular construction, the “MG” system can be easily mounted to a standard DIN rail (35mm), requires minimal wiring, and can be easily expanded for future upgrades.
- Up to 64 connectable gauges
- Input resolutions: 0.1µm, 0.5µm, 1µm, 5µm, and 10µm.
- Compatible with RS-232C, BCD
- Operating voltage: 12-24VDC
- DIN rail mounting (35mm)
Main Module
| Model |
MG10-P1
|
MG10-P2
|
| Power source |
Supply voltage |
DC12-24V(11-26.4V) Min startup time: 100ms or less
|
| Power consumption |
2.0W + total power consumption for connected modules
|
| Inrush current (10ms) |
10A or less (when maximum number of modules are connected)
|
| Power supply protection |
Fuse (5A fuse is built in)
|
| Communication |
Communication I/F |
RS-232C (EIA-232C or equivalent)
|
| Baud rate setting |
2400 / 9600 / 19200 / 38400 bps (set with DIP switch)
|
| Data length |
7 / 8 bit (set with DIP switch)
|
| Stop bit |
1 / 2 bit (set with DIP switch)
|
| Parity |
non / OCD / EVEN (set with DIP switch)
|
| Delimiter |
CR / CR+LF (set with DIP switch)
|
| Linkage function |
Maximum number of linkages |
16 (total of counter modules: 64)
|
| Maximum length of linking cable |
10m
|
| I/O |
Input format |
source input (+COM)
|
sink input (-COM)
|
|
Photo coupler insulation, external power: DC5 – 24V
|
| Output format |
sink type(-COM)
|
source type (+COM)
|
|
Photo coupler insulation, external power: DC5 – 24V
|
| Input signal |
reset, pause, start, latching, and data out trigger to whole channels
|
| Output signal |
intergrated alarm
|
| Connectable modules |
Counter modules |
MG20-DK, MG20-DG, and MG-20DT (available for mixed use, up to 16 modules)
|
| Interface modules |
MG30-B1, MG30-B2
|
Counter Module
| Model |
MG20-DK
|
MG20-DG
|
MG20-DT
|
| Power Consumption |
1W + power consumption for connected gauge
|
1.4W (connected to DG-B) / 0.5W (connected to DL-B)
|
0.8W
|
| Measuring unit input |
Corresponding gauge |
DK series (A/B quadrature input)
|
DG-B series, DL-B/ DL-BR series
|
DT series
|
| Allowable response speed |
10 / 5 / 1 / 0.5 / 0.1 &mirco;m;
|
10 / 5 / 0.5 µm
|
5µm (DT12/32) 1µm(DT512)
|
|
Set with DIP switch
|
| Maximum response speed |
Subject to the specification of the connected gauge
|
1 m/s
|
| Reference point |
REF-LED (reference point loaded) shows on the display after the reference point is detected. Set "0" to preset value on the counter when the reference point is detected
|
-
|
| Others |
Alarm |
S-ALM LED activates by excess speed / acceleration of measuring unit, C-ALM LED activates by excess speed of the internal circuit of counter.
|
|
Alarm display is cancelled by reset command from MG10 or with the reset button of main unit
|
Interface Module
| Model |
MG30-B1
|
MG30-B2
|
| Power consumption |
1W
|
| I/O |
Input format |
source input (+com)
|
sink input (-com)
|
|
Photo coupler insulation, external power: DC5-24V
|
| Ouput format |
sink type (-com)
|
source type (+com)
|
|
Photo coupler insulation, external power: DC5-24V
|
| Input signal |
DRQ / channel address / measuring mode shifting / comparator shifting / reset / start / posing / reference point loaded
|
| Output signal |
BCD data (6 digits) / READY / code/ GO/NOGO output / aram / reference point loaded
|
| Output setting |
timer (1~128ms) / OUT / OR / polarity (set with internal DIP switch)
|
�
| All models |
Operating temperature |
0~50°C (No condensation)
|
| Storage temperature |
-10~+80°C (20~90% RH)
|
|