LY72
 
Download LY72 Spec Sheet
 

For measurements and control in diverse field uses. Optional output boards available.

  • RS-232C standard function
  • Peak Hold Function Convenient for Statistical Measurement
  • Convenient External Input Functions for Automatic Measurement
  • Display Resolution Switching
  • Data Storage
  • Reset / Preset / Restart
  • Detecting Reference Point of Measurement Unit
  • Scaling
  • Flicker Control
Specifications
Model
LY72
Specifications by application
Applications as gauge (set axis labels A, B and C)
Applications as scale (set axis labels X, Y and Z
Display
7 digits and minus display, color amber
Number of connectable axes
1 to 3 axis
Display data
Current (1st axis, 2nd axis, addition axis), maximum, minimum and peak-to-peak values
Current (1st axis, 3rd axis, addition axis)
Measuring unit input resolution
Standard: 0.1µm, 0.5µm, 1µm, 5µm, 10µm, 1s, 10s, 1min, 10min
Expanded: 100µm, 50µm, 25µm, 20µm, 2µm, 0.5µm, and 1 can be added
Input signal
A/C quadrature signal, Z signal (Confroms to EIA-422)
Display resolution
Measuring unit input resolution or higher and supported inch units
Inch Basic: 0.000005", 0.00001", 0.00005", 0.0002", 0.0005"
Inch: Expanded: 0.000002", 0.0001", 0.001", 0.002", 0.005"
Minimum input phase difference
100ns
Alarm display
Measuring unit disconnected, Excess speed, Maximum display amount exceeded, Power failure, Error in stored data
Reset
Current value reset, Alarm cancel
Restart
Restart of peak value calculation for each axis / all axes
-
Preset
It is possible to store / edit up to three values for each axis.
Master calibration function
The master calibration value is relocated when going past the reference calibration reference point point after the power is turned on.
-
Datum point operations
It is possible to store/edit one value for each axis (when not using the point master calibration function).
Reference point operations
It is possible to store/edit one value for each axis (when not using the point operations master calibration function).
Hold function

Selectable from latch and pause
Latch: Display held while latched (display hold)
Pause: Peak calculation stopped while pasued (Peak calculation hold)

Display hold
Linear compensation
A fixed compensation amount is applied to the measuring unit's count value. Compensation amount standard ±600µm/m (Expanded: ±100µm/m)
Scaling
Scaling factor: 0.100000 to 9.999999
RS232C
Data format: All axes on same line / New line for each axis Peak-to-peak value
Transfer rate: 38400/19200/9600/4800/2400/1200 bps
Parity: None / Odd / Even
Stop bit: 1 or 2
Data length: 8 bits or 7 bits
Timer
Off / 0.2 / 0.5 / 1 / 5 / 10 / 30 / 60 / 300 seconds
-
Output data selection
Current value / Maximum value / Minimum value
Current Value
Power supply
DC 12V Rating 0.75A Max, 1A AC 100V to 240V ±10% When using the AC adaptor PSC-22 (For US Only) or PSC-23 (For Europe and other countries)
Power consumption
MAX. 32VA connected at the AC adaptor
Operating temperature
0 to 40 °C (no condensation)
Storage temperature
-20 to 60 °C (no condensation)
Mass
Approx. 1.5kg