Magnescale @ Industeq, an Authorized Distributor Industeq, Inc.®
Authorized Distributor
Phone: 281.565.8600
Fax: 281.565.8601
 
Home Espanol Products Manuals Contact Links
 
Products
Digital Readouts
Linear Encoders
Digital Gauges
Measuring Accessories
Feedback Scales
Cables & Adapters
 
Packages
Grinder Packages
Latheman Packages
Millman Packages
EDM Packages
 
Support
Contact Us
FAQ's
Manuals
Compatibility Chart
Industeq Inc.
Magnescale Co., Ltd.
 
 
Back
 
LY71
 
Download LY71 Spec Sheet
 

For measurements and control in diverse field uses. Optional output boards available.

  • Various outputs are enable by mounting extension boards
    • BCD Output (Option)
    • Comparator Function: Relay / Open Collector (Option)
  • Peak Hold Function Convenient for Statistical Measurement
  • Convenient External Input Functions for Automatic Measurement
  • Display Resolution Switching
  • Data Storage
  • Reset / Preset / Restart
  • Detecting Reference Point of Measurement Unit
  • Scaling
  • Flicker Control
Specifications
Model
LY71
Display
7 digits and minus display, color amber
Number of connectable axes
1 or 2 axes (2-axis function available: addition only is displayed when adding)
Display data
Current (1st axis, 2nd axis, additiona axis), maximum, minimum, and peak-to-peak values
Measuring unit input resolution
Standard: 0.1µm, 0.5µm, 1µm, 5µm, 10µm, 1 s, 10 s, 1 min, 10 min
Expanded: 100µm, 5Oµm, 25µm, 20µm, 2µm, 0.05µm, and 1 can be added.
Input signal
AlB quadrature signal, Z signal (Confonns to EIA.-4221
Display resolution
Measuring unit input resolution or higher and supported inch units
Inch: Basic: 0.000005"", 0.00001"", 0.00006"", 0.0002"", 0.0006""
Inch: Expanded: 0.00002"", 0.0001"", 0.001"", 0.002"", 0.006""
Minimum input phase difference
100 ns
Alarm display
Meesuing unit disconnected, Excess speed, Maximumm display amount exceeded, Powar failure, Error in stored data
Reset
Current value reset, Alarm cancel
Restart
Restart of peak value calculation for each axls/all axes
Preset
It is possible to store/edit up to three values for each axis.
Master calibration function
The master calibration value is relocated when going past the reference calibration reference point point after the power is turned on
Datum point operations
It is possble 10 store/edit one value for each axis (when not using the point master calibration function).
Reference point operations
It is possible to store/edit one value for each axis (when not using the point operations master calibration function).
Hold function
Selectable from latch and pause
Latch: Display held while latched (Display hold)
Pause: Peak calculation stopped while paused (Peak calculation hold)
Linear compensation
"A fixed compensation amount is applied to the measuring unit's count value. Compensation amount Standard: ±600µm/m (Expanded: ±1000µm/m)"
Scaling
Scaling factor: 0.100000 to 9.999999
Power supply
DC 12V Rating, 0.75A Max, 1A AC 100V to 240V ±10% when using the AC adaptor PSC-22 (For US Only) or PSC-23 (For Europe and other countries)
Power consumption
MAX, 32VA connected at the AC adaptor
Operating temperature
0 to 40 °C (no condensation)
Storage Temperature
-20 to °60 C (no condensation)
Mass
Approx. 1.5kg