LY51 - Discontinued - Replaced with LY71
 
 
Download LY51 Spec Sheet
 

Multifunction display with various replaceable expansion I/O boards.

  • Compact design. Suitable for panel mounting.
  • Selectable display resolution
  • Five different replaceable I/O boards. Up to 3 boards can be installed at a time
    • Comparator (Relay output type)
    • Comparator (Open collector output type)
    • BCD (Open collector output)
    • RS-232C
    • A/B phase output
  • Reset / preset / recall
  • Peak hold function for measuring max. / min. / peak-to-peak values.
  • Add/Sub Function
  • Zero point detection
  • Data latch
  • Data storage
  • Linear error compensation
  • Various controls and data analyses by PLC's and computers
  • Inch / metric display
Specifications
Expansion I/O Boards
Model LY51
No. of connectable axes 2
No. of display axes 1
Display Main 7 digits, LED display
(leading zero suppress, floating minus sign)
Aux Two 7 digits, green LED display (leading zero suppress,
floating minus sign), 16 digits message display
Display resolution Varies with the transducer (0.1 µm with DE-B gauge)
Max. response speed Varies with the transducer
Reset/Preset/Recall By key operations or external input
Peak hold function Max./ min./ peak-to-peak values
ADD/SUB A+B, A-B, B-A
Linear error
compensation
When table moves a certain distance, a unit of compensation
value is added or subtracted for linear compensation
Zero point detection Used with a transducer having a zero point,
LY51 detects the zero point
Data latch Output latch and display latch
Data storage Preset value and the value that was displayed before
power-off are stored in non-volatile memory
Alarm display 1. Power interrupt 2. Max.response speed exceeded
3. Error in stored data 4. Transducer disconnected
Operating temperature 0 °C to 40 °C / 32 °F to 104 °F (No condensation ; see note 1)
Storage temperature -20 °C to 60 °C / -4 °F to 140 °F
Power supply 100 V AC to 230 V AC ± 10%
Power consumption 30 VA
Mass Approx. 2 kg/ 4.41 lbs
BCD Unit LZ51-B
Output 7-digit parallel data (4 bits x 7 digits), sign (1 bit), READY
signal (1 bit), positive/negative logic selectable
Electrical Open collector (48 VDC max.); Ic=300 mA
Output IC: SN75468NS
Lash input 5 to 24VDC photo coupler; BCD output alone or
both BCD output and display can be latched
Comparator Unit LZ51 - K/R
Comparison data Current value, max. value, min. value, p-p value
Upper/lower limit settings Selectable from max. of 16 sets (max.) of data
(1 set consists of 1 to 4 comparison data)
Go/NoGo evaluation 5 points, Open collector (24 VDC max.);
Ic=300 mA; Output IC: SN75468NS; relay output
Ext. input 5 VDC to 24 VDC photo coupler
Display When comparison is made with another value
than current value, the main display can be set
to show either max., min. or p-p value in
addition to the current value
RS-232C Unit LZ51-C
Transfer Rate 600, 1200, 2400, 4800, 9600, 19200 bps
Stop bit 1 or 2 bits
Parity Odd, even, no parity
Data length 7 or 8 bits
Data processiing speed 20 data/ s (at 9600 bps)
A/B phase Unit LZ51-H A/B phase output (1st or 2nd axis)
Differential 75113 and open collector 7407