| Model |
MJ500 |
MJ600 |
MJ700 |
| Power supply |
5 V (4.5 V to 8 V) |
| Power consumption |
4 W |
| Output interface |
Line driver (EIA-422) |
| Outputs |
A/B phases, Z phase, U/V/W phases, alarms |
| Number of divisions |
400, 360, 300, 240, 120, 100, 80;
1/2 of each of these (which does not satisfy the synchronized reference point specifications.) |
1024, 1000, 960, 800, 720, 640, 512, 500;
1/2 of each of these (which does not satisfy the synchronized reference point specifications.) |
4000, 3600, 2560, 2400, 2000, 1800, 1280, 1200;
1/2 of each of these (which does not satisfy the synchronized reference point specifications.) |
Maximum response
frequency |
400 divisions |
20 KHz (24.0 m/min on a scale where = 20 ?m) |
1024 divisions |
6 KHz (7.2 m/min on a scale where = 20 ?m) |
4000 divisions |
1 KHz (1.2 m/min on a scale where = 20 ?m) |
| 300 divisions |
28 KHz (33.6 m/min on a scale where = 20 ?m) |
800 divisions |
8 KHz (9.6 m/min on a scale where = 20 ?m) |
3600 divisions |
1.1 KHz (1.3 m/min on a scale where = 20 ?m) |
| 200 divisions |
42 KHz (50 m/min on a scale where = 20 ?m) |
640 divisions |
10 KHz (12.0 m/min on a scale where = 20 ?m) |
2400 divisions |
1.8 KHz (2.1 m/min on a scale where = 20 ?m) |
| 120 divisions or less |
70 KHz (84 m/min on a scale where = 20 ?m) |
500 divisions |
15 KHz (18.0 m/min on a scale where = 20 ?m) |
1200 divisions |
4.7 KHz (5.6 m/min on a scale where = 20 ?m) |
| Minimum phase difference |
100 ns |
| Sin, Cos signal |
0.6 Vp-p to 1.2 Vp-p with 120 ω load |
0.8 Vp-p to 1.2 Vp-p with 120 ω load |
| Compensation range |
0.75 Vp-p to 1.2 Vp-p |
0.9 Vp-p to 1.2 Vp-p |
| Reference point signal |
0.2 V to 1 Vp-p with 120 ω load |
0.2 V to 1 Vp-p with 120 ω load |
| Alarms |
Speed alarm (minimum phase difference time or maximum response frequency) Level alarm (0.6 Vp-p or less) Minimum alarm time: approximately 400 ms |
Speed alarm (minimum phase difference time or maximum response frequency) Level alarm (0.7 Vp-p or less) Minimum alarm time: approximately 400 ms |
| Hysteresis |
/ 2048 |
| Linearity |
± / 1024 |
| System startup time |
Within 0.5 seconds after the power comes on line |
| External dimensions |
138 x 93 x 26 (mm) / 5.43" x 3.66" x 1,024" including protrusions |
| Operating temperature |
0 °C to 45 °C / 32 °F to 114 °F |
| Storage temperature |
-20 °C to 60 °C / -4 °F to 140 °F |
| Mass |
350g/ 0.772 Ibs |
| Supplied accessories |
Manual, output connector, connector cap, mounting screws |
| Options |
SET-P15-1 (for external reference point) Scale extension cable, external reference point extension cable
Output connector with cable |