LH51/52 - Discontinued | Replaced By LH70/71
 
LH51 Digital Readout
 
Download LH51/52 Spec Sheet
 

Compact display with numerous functions for milling machines (LH51) and lathes (LH52)

  • Selectable display resolution
  • Selectable ABC/INC display
  • Linear error compensation
  • Standard functions: reset, preset, recall, data storeage, datum point memory, midpoint calculation, and zero point detection
  • Milling functions (LH51): touch sensor and bolt holt circle
  • Lathing functions (LH52): hold, addition, and tool offset
  • Inch/metric display
Display Specifications
Model
LH51-1
LH51-2
LH51-3
LH52-3
No. of connectable axes
1
2
3
3
No. of display axes
1
2
3
2
Display
7 digits, LED display, mode indication (leading zero suppress, floating minus sign)
Display resolution
Varies with the transducer (0.5 µm with Magnescale)
Max. response speed
Varies with the transducer (60 m/min with Magnescale)
Reset
By key operation or external reset
Preset
By key operation
Recall
Data stored by preset can be recalled by key operation
Linear error compensation
When the table moves a certain distance, a unit length is added or subtracted from the displayed value (linear compensation)
256 compensation values; maximum: ± 600 µm/m
Absolute / Incremental
With the datum point set at any point on the scale, the absolute distance from the point can be displayed while machining in the INC mode
Datum point memory
Set by key operations
Touch sensor
Used with the optional Touch Sensor, LH51 detects the datum plane 1.Hold 2.Load 3.Centering
-
Zero point detection
Used with a transducer having a zero point, LH51/52 detects the zero point and reproduces a datum point
Bolt hole circle
-
Number of divisions: 2 to 360; offset
angle: 0° to 359.999° in 0.001° steps
-
Midpoint calculation
In the INC mode, the displayed value can be halved by a simple key operation
Hold
-
The display value is held and a tool offset can be set with a key switch
Addition function
-
2-axis addition (Z1 + Z2) can be displayed
Tool offsets
-
Max. 9
Data storage
Preset value and the value that was displayed before power-off are stored in non-volatile memory
Alarm dislay
1. Power interrupt 2. Max.response speed exceeded 3. Error in stored data 4.Scale disconnected
Operating temperature
0 °C to 40 °C / 32 °F to 104 °F (No condensation ; see note 1)
Storage temperature
-20 °C to 60 °C / -4 °F to 140 °F
Power supply
100 V AC to 230 V AC ± 10 % 50/60 Hz
Power consumption
Max. 35 VA
Mass
Approx. 1.6 kg /3.53 lbs